题目:Stress-Induced Dual-Phase Structure to Accelerate Degradation of the Fe Implant
摘要:Fe is considered as a potential candidate for implant materials, but its application is impeded by the low degradation rate. Herein, a dual-phase Fe30Mn6Si alloy was prepared by mechanical alloying (MA). During MA, the motion of dislocations driven by the impact stress promoted the solid solution of Mn in Fe, which transformed α-ferrite into γ-austenite since Mn was an austenite-stabilizing element. Meanwhile, the incorporation of Si decreased the stacking fault energy inside austenite grains, which tangled dislocations into stacking faults and acted as nucleation sites for ε-martensite. Resultantly, Fe30Mn6Si powder had a dual-phase structure composed of 53% γ-austenite and 47% ε-martensite. Afterward, the powders were prepared into implants by selective laser melting. The Fe30Mn6Si alloy had a more negative corrosion potential of −0.76 ± 0.09 V and a higher corrosion current of 30.61 ± 0.41 μA/cm2 than Fe and Fe30Mn. Besides, the long-term weight loss tests also proved that Fe30Mn6Si had the optimal degradation rate (0.25 ± 0.02 mm/year).
链接:https://doi.org/10.1021/acsbiomaterials.1c01612